QUADRUPLE SPRING TYPE C VARIABLE SPRING HANGERS

Quadruple Spring Type C Spring Can

Furnished with two lugs for attachment to the building structure. These two lugs permit the use of an Fig 278 eye rodFig 55L, or a single plate for attachment where headroom is limited. Being a quadruple spring can design, it is intended for applications where more vertical travel will occur than can be handled by the standard Figure 268Figure 98 or Triple Spring Hanger.

  • DIMENSIONS:

    Triple or Quadruple Type C Spring Can

    For dimensions not listed below, see Figure B-268.

    Quadruple Spring Can Dimensions

    Attachment rods and nuts not supplied. For dimensions not listed, see Figure B-268.

  • How to use hanger selection table: In order to choose a proper size hanger, it is necessary to know the actual load which the spring is to support and the amount and direction of the pipe line movement from the cold to the hot position. Find the actual load of the pipe in the load table. As it is desirable to support the actual weight of the pipe when the line is hot, the actual load is the hot load. To determine the cold load, read the spring scale, up or down, for the amount of expected movement. The chart must be read opposite from the direction of the pipe’s movement. The load arrived at is the cold load. If the cold load falls outside of the working load range of the hanger selected, relocate the actual or hot load in the adjacent column and find the cold load. When the hot and cold loads are both within the working range of a hanger, the size number of that hanger will be found at the top of the column.

    Should it be impossible to select a hanger in a particular series such that both loads occur within the working range, consideration should be given to a variable spring hanger with a wider working range or a constant support hanger. The cold load is calculated by adding (for up movement) or subtracting (for down movement) the product of spring rate times movement to or from the hot load.

    Cold load = (hot load) ± (movement) x (spring rate) A key criteria in selecting the size and series of a variable spring is a factor known as variability. This is a measurement of the percentage change in supporting force between the hot and cold positions of a spring and is calculated from the formula:
    Variability = (Movement) x (Spring Rate) / (Hot Load) If an allowable variability is not specified, good practice would be to use 25% as recommended by MSS-SP-58.

    Spring Can Series Selection Table Size 0-9

    Spring Can Series Selection Table Size 10-22

    General rule for series selection use Fig. 82 for up to 1⁄2″ of movement, up to 1″ use Fig. B-268, up to 2″ use Fig. 98, up to 3″ use a Triple, up to 4″ use a Quadruple. Double check to assure desired variability is achieved.

  • INSTALLATION DRAWINGS:

    Type C Spring Can Installation Drawing 1

    Type C Spring Can Installation Drawing 2

    Type C Spring Can Installation Drawing 3

     

    The above drawings represent some common installations of the pipe support represented on this page. Each drawing represents the installation of the Fig 268, Fig 82, or Fig 98, but is also representative of the Triple and Quadruple Spring Cans. Installation types and configurations are not limited to the drawings above, but should always follow the manufacturers guidelines for application and installation.

    TRAVEL STOP:

    The functional design of the pre-compressed variable spring hanger permits the incorporation of a two-piece travel stop that locks the hanger spring against upward or downward movement for temporary conditions of underload or overload. The complete travel stop, the up travel stop only for cold set purposes or the down travel stop only which may be employed during erection, hydrostatic test (Anvil permits a hydrostatic test load of 2 times the normal operating load for the spring hanger) or chemical cleanout will be furnished only when specified. The travel stop is painted red and is installed at the factory with a caution tag attached calling attention that the device must be removed before the pipe line is put in service. Permanently attached travel stops available upon request.

    Spring Can Travel Stop

    ADJUSTMENT OF HANGER:

    Once installed in the line; the hanger should be adjusted until the load indicator moves to the white button marked “C” (cold position). On inspection of the system, after a reasonable period of operation, the load indicator should be at the red button marked “H” (hot position). If it is not, the hanger should be readjusted to the hot position. No other adjustment is necessary.

Note: All material included on this page is informational only, and should not be used as one’s sole source for design purposes. STS Industrial, Inc. and its affiliates do not guarantee the accuracy of the information on this site, and retain no liability for the use or misuse of the information contained on this site.

Sources: Anvil International Pipe Hangers and Supports, Carpenter and Paterson Pipe Support Hardware